Virteche
Guideschevron_rightServers

Servers · 9 min read · Updated

First Checks on a New Dedicated Server

The first hour on a new dedicated server is the cheapest time to find a problem. Before moving anything onto it: confirm the CPU, memory and drives are what you ordered, read each drive's health, check the RAID array is in sync, run the CPU and memory hard for a while, and set up alerts so a failing disk emails you instead of surprising you. Commands are for Ubuntu or Debian as root or with sudo.

1. Is It What You Ordered?

lscpu | grep -E 'Model name|^CPU\(s\)|Thread|Socket'
free -h
lsblk -o NAME,SIZE,TYPE,MODEL,MOUNTPOINTS
sudo dmidecode -t memory | grep -E '^\s+(Size|Speed|Type):' | sort | uniq -c

Check the CPU model and thread count, total memory, and the number and size of drives against your order.

2. Read the Drives' Health

sudo apt install -y smartmontools nvme-cli
sudo smartctl -H -A /dev/sda          # each SATA/SAS drive
sudo nvme smart-log /dev/nvme0        # each NVMe drive

For hard drives and SATA SSDs, Reallocated_Sector_Ct, Current_Pending_Sector and Offline_Uncorrectable should be zero. For NVMe, critical_warning and media_errors should be zero. Note Power_On_Hours and percentage_used as a baseline to compare with later.

3. Check the RAID

For Linux software RAID (mdadm):

cat /proc/mdstat
sudo mdadm --detail /dev/md0

Every array should show all members up — [UU] for a two-drive mirror — and state clean or active. A new array may still be resyncing; that is normal, and it is best to let it finish before heavy testing. On ZFS the equivalent is zpool status, which should say ONLINE with no errors.

4. Burn In the CPU and Memory

sudo apt install -y stress-ng lm-sensors
stress-ng --cpu 0 --vm 1 --vm-bytes 75% --timeout 30m --metrics-brief
# in a second session, watch temperatures
watch -n 5 sensors

Thirty minutes with every core busy and most of the memory in use should finish without errors, crashes or temperatures climbing without limit. Then look for anything the kernel noticed:

sudo journalctl -k -p warning --since "1 hour ago"
sudo apt install -y rasdaemon && sudo ras-mc-ctl --summary   # memory (ECC) errors

5. Measure the Disks and Network

A one-minute random-read test gives a baseline to compare with if things feel slow later:

sudo apt install -y fio
sudo fio --name=randread --filename=/root/fio.test --size=4G --rw=randread --bs=4k \
    --iodepth=32 --ioengine=libaio --direct=1 --runtime=60 --time_based --group_reporting
sudo rm /root/fio.test

For the network, iperf3 between this server and another machine you control gives a cleaner number than a speed-test website.

6. Get Told When a Drive Starts Failing

smartd watches every drive and mdadm watches the arrays; both send email when something changes. Both send through the mail command, so install a mail relay and that command first (for example sudo apt install msmtp-mta bsd-mailx, with msmtp pointed at your mail provider), then:

# /etc/smartd.conf — replace the DEVICESCAN line with:
DEVICESCAN -a -o on -S on -s (S/../.././02|L/../../6/03) -m [email protected]

# /etc/mdadm/mdadm.conf — change the existing MAILADDR line to:
MAILADDR [email protected]

sudo systemctl restart smartmontools
sudo systemctl restart mdmonitor                # it only reads MAILADDR when it starts
sudo mdadm --monitor --scan --test --oneshot    # sends a test message

The smartd line runs a short self-test every night at 02:00 and a long one on Saturdays at 03:00.

Then: Secure It and Back It Up

Work through the hardening checklist — it applies to dedicated servers just as much — and set up off-site backups before real data arrives; the Borg guide takes about ten minutes.

Common Questions

  • Something does not match what I ordered. What now?

    Open a support ticket from your dashboard with the output of the command that shows it (lscpu, free -h or lsblk). Hardware problems are far easier to sort out before your data is on the machine.

  • Which SMART values actually matter?

    On hard drives: reallocated, pending and offline-uncorrectable sectors should all be zero, and should stay zero. On NVMe: media and data integrity errors should be zero and critical warning 0x00; percentage used is wear, and is fine well below 100%.

  • Will the burn-in harm the server?

    No. Servers are built to run flat out. A burn-in only brings forward failures that would otherwise happen later, under your real workload.

  • Is RAID a backup?

    No. RAID keeps the server running when a drive fails; it faithfully mirrors deletions, corruption and ransomware too. Back up to somewhere else as well.

AMD EPYC and Ryzen machines in Ashburn and Dallas, with the whole machine to yourself.

See dedicated servers

Keep Reading